AHU (air handling unit)

  • Description
  • Inquiry

 

AHU (air handling unit) covers vertical (air volume from 2000 ~ 60000m3 /h), horizontal (wind increased from 2000 ~ 60000m3/h), and ceiling-type (air volume from 1000 ~ 16000m3/h) three series of air-handling unit to meet customers’ need of cooling, heating, humidification, dehumidification and so on. It is widely applied in hotels, theaters, shopping malls, office buildings and a variety of places requires comfortable environment. It also can be used in electronics, chemical, medical, pharmaceutical, cigarettes, food, light engineering and other industrial buildings.

Our AHU Projects in South America

 

Parameters of the AHU

Model DM260-50HC DM310-60HC
Clean Room Class E E
Quality Target Temp. 20 °C – 22 °C, RH 55-60% Temp. 20 °C – 22 °C, RH 55-60%
Capacity 450.000 Btuh 540.000 Btuh
Flow 15.000 CFM 18.000 CFM
Condensing unit 50 HP ( 25 HP * 2 unit) 60 HP ( 20 HP * 3 unit)
Static Pressure  6″ WG (1500 Pascal) 6″ WG (1500 Pascal)
ACH 20 X 20 X
AHU Double Skin PU foam 50 mm Double Skin PU foam 50 mm
Thickness 0.45 mm, Powder Coating Thickness 0.45 mm, Powder Coating
C/W: Magnehelic + Sight glass C/W: Magnehelic + Sight glass
Filters Pre G4 + Medium F8 + HEPA H13 Pre G4 + Medium F8 + HEPA H13
Control Operation Single Chip Microcomputer & Touch Keypad Single Chip Microcomputer & Touch Keypad
Electric Heater 24 kW (8 * @3 kW) 24 kW (8 * @3 kW)
Flow Process Mixing Box + Prefilter G4 + Medium filter
F8 + Coil + Electric Heater + Fan
+ Hepa filter H13
Mixing Box + Prefilter G4 +
Medium filter F8 + Coil + Electric
Heater + Fan
+ Hepa filter H13
Compressor Panasonic Panasonic
Volume Dumper Fresh Air ( 1 pcs) Fresh Air ( 1 pcs)
Volume Dumper Supply Air ( 1 pcs) Supply Air ( 1 pcs)
Volume Dumper Return air ( 2 pcs) Return air ( 2 pcs)
Partial material configuration of cabinet
No.1 Frame Insulating bridge aluminum alloy frame with imported sealing tape
No.2 Cabinet board structure and cabinet board insulation It adopts double-panel structure, the inner and outer panels are made of color steel plates, and the outer panels are protected by transparent plastic film. The insulation material is high-pressure infused polyurethane, and the insulation thickness: 50mm
No.3  Mixing section New and return air outlets with manual air volume regulating valve, with inspection door
No.4  Primary effect G4 plate non-woven fabric primary filter
No.5 Medium-efficiency
section
F8 bag-type non-woven medium-efficiency filter with Dwyer differential pressure gauge
No.6 Surface cooling
section
high quality copper tube blue wave aluminum fin direct expansion table cold coil tube with stainless steel water collecting pan
No.7 Heating section Electric heater
No.8 Fan section A. Italian brand NICOTRA /Zhejiang Lionke / Guangdong Detong fan
B. Siemens Beide/ Guangdong Jiangsheng Motor or equivalent brand Motor,   C. with access door, window
No.9 Current sharing section With current sharing plate, access door
No.10 High-efficiency section H13 box-type high-efficiency filter with Dwyer differential pressure gauge
No.11 Air supply section Air supply port with manual air volume regulating valve and inspection door
Main material configuration of refrigeration part
No.1 Compressor Japanese Panasonic compressor or equivalent brand (R407c refrigerant)
No.2 Condenser Set of finned copper tube blue wave aluminum fins
No.3 Expansion valve Shangheng
Main material configuration of electric control system
No.1 Fan, motor starting device Magnetic contactor, overload protection, high and low voltage protection, compressor phase loss protection, transformer
No.2 Temperature and humidity controller & temperature and humidity sensor Deep Blue/British League or equivalent brand: (display in English) Temperature controller controls temperature, with temperature display and setting functions,, Touch screen HMI interface monitoring
No.3 Electric control box installation The electric control part is an independent electric control box. The wiring materials and wiring installation connection from the electric control box to the unit are not included. A separate quotation is required according to the actual installation location. The customer provides the power supply to the electric control box.
Power distribution system applicable power range 380V/3N/50HZ
Size of unit
No.1 DM260-50HC Indoor unit size:5800*2000*1930  ;   Outdoor unit size:2280*1060*1600*2sets
No.2 DM310-60HC Indoor unit size:6000*2000*2280  ;  Outdoor unit size:2280*1060*1450*3sets

Why choose DECENT MACHINERY? 

 

 

 

 

Product

Material 1.The thickness of the inner wall of the unit is 25-50mm, and the thickness of the steel plate is 0.4-
2.High strength, light weight, bright color, heat insulation: thermal conductivity of core material,double-layer color steel plate with λ<=0.041w/mk
Sealing strip Multi-color, imported, super soft, non-damaging, excellent sealing strip
Voltage 220V/230V/380V/440V/460V
Refrigerant 1.R22
2.R407c
3.R134a
Accept customer specified refrigerant
Altitude Suitable for areas with an altitude of 4000m
Accessories Motors, fans & compressors Customizable, selectable brand
Motor 100% pure copper core motor
Accessories Imported accessories from Europe, America, Japan and Denmark etc.
     Service Quotation A variety of quotation plans, and flexible quotation plans can be made according to the customer’s target price
Test Support online video inspection, third-party testing and customers in person to the factory for testing
Provide customers with test reports, videos, pictures
Instructions Support multiple languages
Service Technical group dedicated to serving customers, 24*7 hours online free technical communication
Drawing CAD & 3D Drawing

The characteristics of air-handling units:

Frame structure: aluminum framework structure is adopted, which is made of high-strength aluminum alloy. Each corner of the framework is made of special castings, allowing the section bar to plug into it. This structure has the following features:

A: good performance in mechanical strength, light in weight, corrosion resistance, beautiful shape and accurate size.

B: flexible assemblage, very convenient to install, remove and maintenance. Also, it has longer service life than steel structure.

Panel structure:

A: the panel is formed by two layers of colored steel plates. Filler between the layers is high-density polyurethane or polystyrene, which has a better performance in thermal isolation than other materials like glass wool. No thermal bridge will be produced while working in all weather or working conditions.

B: panels are fixed in a special way, with sealing material to strengthen its thermal and air resistance. This structure has the best performance in thermal isolation, noise reduction and intensity, so it can be used in places require high quality of air.

Fan, electrical motor:

A: unit adopts centrifugal fan with both air inlet. The fan runs smoothly in the rigorous static and dynamic balance test.

B: With ball bearings sealed, and functions of pre-lubricating, self-aligning, self-locking, automatic thrust, etc., the fan is maintenance-free in normal use.

C: fans of a small model unit are driven directly by external sub-motor, no belt, and easy to maintain.

Filter: unit filter is coarse plate. Filter material is cleanable convex Nylon net.

Cooler: the selected parameters of surface air cooler are designed by CAD/coi1 software. A standard cooler normally has copper pipes of φ6. It is tightened by an overall rise up of brass strung by corrugated aluminum fin tubes. Staggered copper pipes have good heat transfer performance, low airflow resistance and superior corrosion resistance, ensuring the cooler has a higher heat transfer coefficient and a longer life.

 

Note: 1. method to decide units type: facing the air inlet (i.e., along with air-flow direction), if the inlet and outlet tube is on the left, it is left form, if on the right, it is right form.

2. According to client’s specific need, our company can configure additional electrical protection devices and air quantity speed regulation (including variable frequency controller and thyristor controller).

3. Structures corresponding with the external air duct: as shown below, A is the default choice.

 

Ordering Guide
◆ Please be sure of the size, model, cool and heat quantity and left/right form in selecting air handling unit.
◆ Electrical controller is not part of the unit. However, the electric protector and air quantity speed regulation (including variable frequency controller and thyristor controller) is addable according to clients’ needs. Neither is inlet and outlet air quantity valve part of the unit. Please inform us before ordering if you need it.
◆ Our products are not limited to our routine units. According to clients’ special needs, unit can be equipped with additional electrical (auxiliary) heater, humidifier (steam humidifier, wet membrane humidifier, high-pressure spray humidifier and electrode humidifier), silencerand so on.
Our company follows the principle of constantly improving our products. Please kindly excuse us if we do not inform you in time about changes or improvement of product performance, specifications, and materials, and keep in touch with us to obtain the latest information.
If you are interested in our product, please feel free to contact us.  Email: [email protected]

For more product information, please click on the picture below

01
02
3_副本
04_副本

Contact Us






Online Service
Live Chat